The ForneyLink display provides you with all of the options needed to manage the testing of your ForneyVault® specimens.
Table of Contents:
ForneyLink on an automatic machine.
1 | Start Test | Start selected test | 19 | Machine Setup | Enter the Machine Setup menu. |
2 | Stop Test | Stop Selected test. | 20 | Reprint Test Report | Reprint tested specimen report. |
3 | Sample | Manage Sample menu. | 21 | Measure | Measurement menu for the selected specimen. |
4 | Set | Displays selected Set. | 22 | DiamAVg | The average diameter of the specimen. |
5 | Specimen | A quick selection of the specimens in a set. | 23 | LenghtAvg | The average length of the specimen. |
6 | Manage | Manage specimens in selected sets. | 24 | Age | Age of specimen to be tested. |
7 | Load | View load placed on the specimen. | 25 | Weight | Weight of Specimen |
8 | Stress | View Stress placed on the specimen. | 26 | Density | The measured density of the specimen to be tested. |
9 | Max Load | Max load placed on the specimen. | 27 | Corr. Factor | ASTM defined correction for specimen size. |
10 | Max Stress | Max stress placed on the specimen. | 28 | Ends Prep | Specimen ends preparation to be used in the test. |
11 | Ramp Rate | Display of specified speed for testing the specimen. | 29 | Exp. Strength | Display of specimen's expected strength. |
12 | Test Counter | Count of tests performed. | 30 | Preload | Set the load applied to the specimen prior to achieving the specified ramp rate. |
13 | Jog Advance | Move the machine piston forward. | 31 | Ramp Rate | Set the specified speed for testing the specimen. |
14 | Retract | Move the machine piston backward. | 32 | Break Pct. | Select stress percentage from max stress to detect break. |
15 | Show Graph | Show stress vs time graph of tested specimen. | 33 | Test Stop | Stop the test at a specific load, stress, or position (on position-equipped machines) instead of loading to specimen failure. |
16 | Logout | Log the current user off ForneyLink. | 34 | Ask for Break Type? | Enable prompt for break type after the test completes. |
17 | Diagnostics | Enter the diagnostic menu. | 35 | Language Menu | Select ForneyLink's displayed language. |
18 | Verify Calibration | Enter the Machine Calibration menu. |
ForneyLink on a manual machine.
1 | Start Test | Start selected test | 18 | Verify Calibration | Enter the Machine Calibration menu. |
2 | Stop Test | Stop Selected test. | 19 | Machine Setup | Enter the Machine Setup menu. |
3 | Sample | Manage Sample menu. | 20 | Reprint Test Report | Reprint tested specimen report. |
4 | Set | Displays selected Set. | 21 | Measure | Measurement menu for the selected specimen. |
5 | Specimen | A quick selection of the specimens in a set. | 22 | DiamAVg | The average diameter of the specimen. |
6 | Manage | Manage specimens in selected sets. | 23 | LenghtAvg | The average length of the specimen. |
7 | Load | View load placed on the specimen. | 24 | Age | Age of specimen to be tested. |
8 | Stress | View Stress placed on the specimen. | 25 | Weight | Weight of Specimen |
9 | Max Load | Max load placed on the specimen. | 26 | Density | The measured density of the specimen to be tested. |
10 | Max Stress | Max stress placed on the specimen. | 27 | Corr. Factor | ASTM defined correction for specimen size. |
11 | Ramp Rate | Display of the speed for testing the specimen. | 28 | Ends Prep | Specimen ends preparation to be used in the test. |
12 | Ramp Rate Target | Display of speed of testing target. | 29 | Exp. Strength | Display of specimen's expected strength. |
13 | Ramp Rate Tolerance | Speed of testing tolerance percentage | 30 | Preload | Set the load applied to the specimen prior to achieving the specified ramp rate. |
14 | Test Counter | Count of tests performed. | 31 | Ramp Rate | Set the specified speed for testing the specimen. |
15 | Show Graph | Show stress vs time graph of tested specimen. | 32 | Break Pct. | Select stress percentage from max stress to detect break. |
16 | Logout | Log the current user off ForneyLink. | 33 | Ask for Break Type? | Enable prompt for break type after the test completes. |
17 | Diagnostics | Enter the diagnostic menu. | 34 | Language Menu | Select FormeyLink's displayed language. |